Product name: RY-ⅡB+Anesthesia Workstation
Model: RY-ⅡB+
Status: Normal
Brand:
Origin: Jiangsu
Quotation:
Number of views: 166
Main parameters
Flow range: (0.25~15) L/min; Temperature range: (15~35)℃;
Product Features
RY-IIB+ anesthesia workstation is a new anesthesia workstation using modern microcomputer control technology, suitable for modern anesthesia surgery . Novel appearance, convenient connection, excellent performance, and preferential price constitute the best performance-price ratio, allowing users to enjoy great value. RY-IIB+ anesthesia workstation has strong practicality. It has been proven through good experiments and tests in clinical practice and has been well received by customers.
Product parameters
Anesthesia machine
1. Working mode: fully closed, semi-closed (0.5~7.5) kPa and semi-open;
2. Gas supply: central pipeline gas supply or gas cylinder supply can be used, with a backup gas source input port. The rated working pressure is 0.4 MPa, and the allowed fluctuation range is (0.27~0.55) MPa;
3. Flow meter: O2: (0.1~10) L/min; N2O: (0.1~10) L/min;
4. Rapid oxygen supply flow: (35~75) L/min;
5. High-precision evaporator: equipped with KT-III type enflurane and isoflurane evaporator
Concentration range: 0~5Vol%;
Flow rate range: (0.25~15) L/min;
Temperature range: (15~35)℃;
Automatic compensation of flow rate, temperature and pressure.
Anesthesia ventilator
1. Inspiratory flow rate: (6~66) L/min;
2. Adjustable tidal volume range: (50~ 1500) mL;
3. Frequency: (6~99) times/min;
4. Inhalation-to-exhalation ratio: 3:1~1:9 (inhalation time 0.3s ~6.0s);
5. Pressure upper limit alarm: (1.0~6.0) kPa (not lower than the lower limit);
6. Pressure lower limit alarm: (0.4~4.0) kPa (delay 4s ~ 15s);
7. Maximum safety pressure: pressure limiting valve exhaust pressure (5.1 ~ 6.0) kPa;
8. Low ventilation alarm: when moisture is exhaled When the volume is lower than the minimum set value, an alarm should be issued within 90 seconds;
9. Bellows tidal volume range: adults: (300~1500) mL; children: (50~300) mL;
10. Power failure alarm: an audible alarm will sound when the power supply is interrupted, and the alarm duration shall not be less than 120s;
11. Gas source interruption alarm: a lower pressure limit alarm will be triggered when the gas source is interrupted;
p>
12. The silence time of the alarm: no more than 120s.
Product name: GSM-Ⅲ(C) anesthesia machine
Model: GSM-Ⅲ(C)
Status: Normal
Brand:
Origin:
Quotation:
Number of views: 317
Product parameters
▲Anesthesia host Parts:
●1. Mode: tightly closed, semi-closed, semi-open
●2. Air supply source: O2, N2O pressure 0.3~0.5MPa
●3. Flow meter: O2, N2O two-tube flow meter 0~10L with linkage mechanism to ensure the oxygen concentration is not less than 25%
●4. Rapid oxygen supply: 35L/min~75L /min
●5. Electronically controlled pneumatic fixed-volume anesthesia ventilator
●6. Low gas source alarm: When the O2 gas source is too low, there will be a sound alarm for more than 7 seconds< /p>
●7. High pressure limit: When the airway pressure exceeds the upper limit set value, the ventilator automatically limits the airway pressure to ensure that the airway pressure cannot continue to rise and ensure safety
●8 .Using a double-ended differential pressure flow sensor, it can measure tidal volume, minute ventilation, respiratory frequency, airway pressure, pressure waveform, flow velocity waveform (bidirectional), upper and lower pressure limits, Real-time monitoring of asphyxia and oxygen concentration
●9. The external suspension system is exquisitely designed and easy to operate
▲Anesthetic evaporation part:
●High-precision imported from the UK ( Penlon tank), double tank (enflurane, isoflurane)
●The evaporator has automatic compensation function for flow, pressure and temperature
●Concentration adjustment range: 0.2~5% VOL
●The evaporator has self-locking and interlocking functions
▲Anesthesia ventilator part:
●1. Applicable: adults and children
●2. Drive: pneumatic electric control
●3. Display: 10.4 color TFT large screen display
●4. Mode: manual, automatic
< p>●5. Tidal volume: 100~1500ml●6. Frequency: 6~60bpm
●7. Breathing ratio: 3:1~1:4 adjustable
●5. p>●8. Upper limit of pressure: 2~6Kpa
●9. Lower limit of pressure: 0.6~2Kpa
●10. Monitoring parameters: tidal volume, respiratory rate, respiration Ratio, peak airway pressure
Product introduction
▲Free configuration:
●Pediatric bellows: 50~300ml
●Pediatric circuit
▲Options:
●End-tidal CO2 monitoring is optional
●An external printer is optional to record alarm events
Product name: Anesthesia machine PN-2000M
Model: PN-2000M
Status: Normal
Brand:
Origin:
p>Quotation:
Number of views: 322
Product parameters
Technical parameters of anesthesia machine
Flow adjustment range:< /p>
N2O:0.1L/min~12L/min,
O2:0.1L/min~12L/min
Rapid oxygen supply flow: 35L/min~ 75L/min
Oxygen supply low-pressure alarm, N2O automatic cut-off:
When the oxygen supply pressure is lower than 0.25Mpa, there will be an audible alarm, lasting no less than 7 seconds,
When the oxygen supply pressure is lower than 0.1Mpa, the N2O flow is automatically cut off.
An, isoflurane evaporator (optional imported or domestic):
Concentration range: 0.25voL%~5voL%
Flow range: 0.25 L/min~15L/min
Temperature range: 15℃~35℃ Automatic compensation of flow, temperature and pressure.
Anesthesia ventilator
Tidal volume: 200mL~1200mL
Respiratory frequency: 10BPM~30BPM
Respiratory ratio: 1:1~ 1:3
Upper pressure limit (limit): 1KPa~6KPa
Lower pressure limit: 0~4KPa
Blow box: 100mL~1500mL
Product introduction
Product description:
PN-2000M anesthesia machine
Equipped with high-precision enflurane and isoflurane evaporators, high-precision N2O and O2 flow meter, emergency oxygen supply device and oxygen low pressure alarm, N2O automatic cut-off. The patient circuit system complies with ISO standards and has manual control of breathing and mechanical ventilation, making anesthesia safer and more convenient.
PN-2000MII type anesthesia ventilator
Microcomputer controlled pneumatic electronically controlled ventilator, intuitive operation and complete functions.
Product name: Multifunctional anesthesia machine PN-200OMD
Model: PN-200OMD
Status: Normal
Brand:
p>
Origin:
Quotation:
Number of views: 349
Product parameters
Technical parameters of anesthesia machine
Flow adjustment range:
N2O:0.1L/min~12L/min,
O2:0.1L/min~12L/min
Rapid oxygen supply flow: 35L/min~75L/min
Oxygen supply low pressure alarm, N2O automatic cut-off:
When the oxygen supply pressure is lower than 0.25Mpa, there will be an audible alarm, and the duration Not less than 7 seconds,
When the oxygen supply pressure is lower than 0.1Mpa, the N2O flow is automatically cut off.
An, isoflurane evaporator (optional imported or domestic):
Concentration range: 0.25voL%~5voL%
Flow range: 0.25 L/min~15L/min
Temperature range: 15℃~35℃ Automatic compensation of flow, temperature and pressure.
Anesthesia ventilator:
Tidal volume: 200mL~1200mL
Respiratory frequency: 10BPM~30BPM
Respiratory ratio: 1:1 ~1:3
Upper pressure limit (limit): 1KPa~6KPa
Lower pressure limit: 0~4KPa
Blow box: 100mL~1200mL
< p>Product introductionProduct description:
PN-2000MD multifunctional anesthesia machine
It consists of an anesthesia machine and anesthesia ventilator. The anesthesia machine microcomputer controls the pneumatic electronically controlled ventilator, with intuitive operation and complete functions. The anesthesia ventilator is equipped with high-precision enflurane and isoflurane evaporators, high-precision N2O and O2 flow meters, emergency oxygen supply device, oxygen supply low-pressure alarm, and N2O automatic cutoff. The patient circuit system complies with ISO standards and has manual control of breathing and mechanical ventilation, making anesthesia safer and more convenient.
Product name: RY-ⅡA anesthesia machine
Model: RY-ⅡA
Status: Normal
Brand:
Origin: Jiangsu
Quotation:
Number of views: 153
Main parameters
Concentration range: 0~5vol%; Temperature range: (15~35)℃; Flow range: (0.25~15)L/min;
Product parameters
Air supply pressure: Rated working pressure 0.4MPa, working pressure Range (0.27~0.55) MPa, gas cylinder or central pipe supply;
Flow rate: O2: (0.1~10)L/min, N2O: (0.1~10)L/min;
Flow control valve: The linkage mechanism between oxygen and laughing gas ensures that the oxygen concentration is not less than 25%. When the oxygen flow control valve is not opened, laughing gas cannot enter the anesthesia respiratory system;
Rapid oxygen supply flow: (35~75) L/min;
Respiratory circuit: Working mode: fully closed, semi-closed, semi-open (1~4) kPa; exhalation and inhalation impedance: no more than 0.6kPa ;
Evaporator: Equipped with KT-II type enflurane or isoflurane evaporator
Concentration range: 0~5vol%;
Temperature range: (15~35)℃;
Flow range: (0.25~15)L/min;
Automatic compensation of flow, temperature and pressure.
Product Introduction
RY-IIA anesthesia machine can meet the basic clinical requirements. The machine has a reasonable layout and simple structure, and is suitable for use in hospitals at all levels. The loop system complies with ISO standards and has various working modes of fully closed, semi-closed and semi-open. It is suitable for children and adults over 4 years old. The case is not limited. When used for children under 4 years old, pediatric products can be purchased from the manufacturer. Anesthesia circuit.
Product name: American VME animal anesthesia machine
Model: VME
Status: Normal
Brand:
Origin: United States
Quotation: Negotiable
Number of views: 193
Product Features
1. Professional closed breathing circuit:
2. Accurate oxygen flow meter with stable output and rapid oxygenation function. With rapid oxygenation function; you can choose to equip it with dual flow meters
3. Equipped with APL automatic pressure relief safety function: to avoid pressure damage to animals caused by excessive air pressure
4. With pressure Detection function
5. Patented air intake valve: allows animals to still breathe the atmosphere after the oxygen supply is stopped.
Ensure the safety of animals in case of accidents
6. Equipped with carbon dioxide absorption system:
7. Equipped with exhalation and inhalation valves: the breathing status of anesthetized animals can be clearly observed: Inhale or exhale
8. Compact structure design, flexible movement, with portable handle, easy to use;
Product name: TIAC-I intravenous anesthesia controller (target controlled pump )
Model: TIAC-I
Status: Normal
Brand:
Origin: Guangdong
Quotation :
Number of views: 199
Main parameters
Precise control: capacity error ±2%
Product features
< p>1. After 18 years of clinical research, it is the only intravenous anesthesia control device that delivers drugs based on Chinese pharmacokinetics and pharmacodynamic parameters, and the anesthesia control is stable;2. Select 7 commonly used clinical methods For intravenous anesthetics, all data come from clinical practice;
3. Use a first-class imported injection system with stable performance;
4. Large LCD screen, Chinese menu interface, easy to operate;
5. There are two drug administration modes: target control mode and constant rate mode. In target control mode, you can choose plasma or effect chamber concentration mode for drug administration;
6. Have independent knowledge Property rights, obtained 3 national patents, published more than 90 academic papers and two books;
Product parameters
Accurate control: capacity error ±2%;
< p>When the battery is fully charged, it can work continuously for >6 hours.Product Introduction
It is the first in China to adopt Chinese intravenous anesthesia parameters and select world-class hardware to develop an "intelligent intravenous anesthesia controller" with independent intellectual property rights.
Based on my own experience and experience, I feel that Beijing Yi’an’s machines are relatively better
This is not to disparage domestic manufacturers. Domestic anesthesia machines are more stable, easier to use and safer than imported machines. There is too much difference. If you are choosing yourself, remember that there are some key components. As long as they are imported, the performance of this kind of anesthesia machine is usually better. Purely domestic ones are not recommended.
We still recommend Dr?ger from Germany and Austria from the United States. Don’t worry about using Meda.