The steps for debugging the cement mortar mixer are as follows:
1. During operation, first turn on the power.
2. Turn the button switch to the program-controlled position, which will automatically complete a slow rotation-stop-fast rotation program. If the twist switch is set to the manual position, the manual three-position switch will complete the above actions respectively, left and right. By moving the handle, the sliding plate drives the mixing pot to move up and down along the dovetail guide rail of the column. The upward movement is used for stirring, and the downward movement is used to remove the mixing pot. The mixing pot is rotated and locked with the eccentric groove of the sliding plate.
3. Before starting up, make preparations, tests and adjustments before starting up.
4. Controller acceptance and electrical operating methods.
5. Pay attention to keeping the whole machine and controller clean. The mixing blades and pots should be cleaned and dried in time after each use. The electrical parts should avoid violent vibrations, stay away from water and high temperatures, and pay attention to dust.