The qualification grade of fire protection design is divided into Grade A and Grade B. ..
(1) Grade A
1, qualification and reputation
This unit has been engaged in the design of special fire-fighting facilities for more than 5 years and has a good social reputation.
2. Technical strength
The total number of technicians engaged in design is not less than 20, and the number of senior engineers is not less than 3; Including electrical, automatic control, water supply and drainage, HVAC and other major technical professionals not less than 3 people; And at least two people in each professional and technical specialty have been engaged in the special engineering design of automatic fire-fighting facilities for more than 5 years, and have passed the examination of relevant fire-fighting majors, with strong fire-fighting professional and technical capabilities.
3. Technical level
To undertake the special engineering design of fire-fighting facilities for more than three large-scale projects, such as automatic fire alarm and its linkage control system, automatic sprinkler system, gas fire extinguishing system, foam fire extinguishing system and smoke control system, which have been completed with good quality and quantity.
4, management and equipment level
The unit has established an effective quality system. Equipped with computers, plotters and other necessary equipment and general design, fire professional design software, with a high level of application.
(2) Grade B
1, qualification and reputation
This unit has been engaged in the design of special fire-fighting facilities for more than 2 years and has a good social reputation.
2. Technical strength
The total number of technical personnel engaged in design is not less than 15, including not less than 2 senior engineers; Including electrical, automatic control, water supply and drainage, HVAC and other major technical professionals of not less than 2 people each; In addition, there are not less than 1 person who have been engaged in the special engineering design of automatic fire-fighting facilities for more than 5 years in various professional and technical specialties and passed the examination of relevant fire-fighting specialties.
3. Technical level
To undertake the special engineering design of fire-fighting facilities for more than three large-scale projects, such as automatic fire alarm and its linkage control system, automatic sprinkler system, gas fire extinguishing system, foam fire extinguishing system and smoke control system, which have been completed with good quality and quantity.
4, management and equipment level
The unit has established an effective quality system. Equipped with computer, plotter and other necessary equipment and general design and fire-fighting professional design software, with general application level.
For more information about project/service/procurement bidding, and to improve the winning rate, please click on the bottom of official website Customer Service for free consultation:/#/? source=bdzd