What are the requirements of Jiangsu green building evaluation standards for indoor environmental quality of public buildings?

In order to implement the economic policy of saving resources and protecting the environment, promote sustainable development, standardize the evaluation of green buildings in Jiangsu Province, and formulate the evaluation standards of green buildings in Jiangsu Province. It is suitable for evaluating newly built, rebuilt and expanded residential buildings and public buildings (office buildings, shopping malls and hotel buildings) in Jiangsu Province. Among them, what are the requirements of Jiangsu Province's green building evaluation standards for the indoor environmental quality of public buildings? The following is a detailed introduction to the requirements of Jiangsu Province's green building evaluation standards for indoor environmental quality of public buildings brought by the construction network for reference.

Ⅰ control term

For buildings with central air conditioning, indoor temperature, humidity, wind speed and other parameters meet the design and calculation requirements in GB 50 189. The fresh air volume meets the design requirements in GB 50 189 Design Standard for Building Energy Efficiency.

There is no condensation and mildew inside and on the surface of the building envelope.

The concentrations of indoor free formaldehyde, benzene, ammonia, radon and TVOC meet the relevant provisions of Code for Indoor Environmental Pollution Control of Civil Building Engineering (GB 50325).

The indoor background noise of hotels and office buildings meets the secondary requirements of indoor allowable noise standard in Code for Sound Insulation Design of Civil Buildings (GBJ 1 18). The indoor background noise level of shopping mall buildings meets the relevant requirements of GB 9670 Hygienic Standard for Shopping Mall (Store) and Bookstore.

The indoor illuminance, uniform glare value and total color rendering index of the building meet the relevant requirements in GB 50034 "Design Standard for Building Lighting".

Ⅱ general terms

Architectural design and structural design have measures to promote natural ventilation.

Indoor air conditioning terminal is adopted, which is convenient to adjust and can improve people's comfort.

The sound insulation performance of building envelope components of hotel meets the first-class requirements in Code for Sound Insulation Design of Civil Buildings (GBJ 1 18).

The plane layout and spatial function arrangement of the building are reasonable, so as to reduce the noise interference of the adjacent space and the influence of external noise on the interior.

The indoor lighting coefficient of more than 75% of the main functional spaces in office and hotel buildings meets the requirements of GB/T 50033 Standard for Lighting Design of Buildings.

There are barrier-free facilities at the entrance of the building and the main activity space.

ⅲ optimal selection

Using adjustable external shading to improve indoor thermal environment.

Establish an indoor air quality monitoring system to ensure a healthy and comfortable indoor environment.

Take reasonable measures to improve the natural lighting effect of indoor or underground space.