Zero test steps: after the elevator replaces or adjusts the main encoder or loses the original test zero, it needs to carry out zero test. The above situations include re-reading and writing SIM cards or replacing GCIO360, which also need to be tested. Set the JMOF switch to 1 (installation and operation); Turn the elevator recall switch to the maintenance position; Adjust the SMLCD menu to Test/VF Test/ZeroPosition and confirm. Press the up (or down) button according to the car position to make the elevator run. Then the elevator will stop after a short distance. Continue to press the up (or down) button until the elevator can run for a long time, and success will be displayed on SMLCD. At this point, the zero test was successful.
Axis self-learning process: after replacing or adjusting the axis absolute value encoder, axis self-learning operation is needed. Drive the elevator to the top of the shaft and level the floor (judge the level according to LUET on the man-machine interface); Set the JMOF switch to the 0 position; Turn the machine room recall and car roof maintenance switch to the normal position; Adjust the SMLCD menu to Command/Special Trip /JLF and confirm; At this time, the elevator will automatically run to the bottom of the shaft at the learning speed; After the elevator stops at the bottom floor of the shaft, the elevator status will be displayed as N, and the elevator learning operation is completed. After learning and running, check the flat floor of the elevator, and if there is any deviation, adjust it by Adj floor leveling.
Call test step; After changing the outgoing printing plate or EBBIO (applicable to the lower version), outgoing test is required. The elevator is operating normally; Adjust the SMLCD menu to command/teach mode and confirm; The elevator will enter JTI mode; Make the elevator run to the required test floor through internal command; /kloc-Leave the elevator within 0/2 seconds and press and hold the up call button for 3 seconds; The external display of the elevator flashes once, and the buzzer in the car buzzes at the same time, and the outgoing call test of this floor is completed; Test other floors in the same way; After all tests are completed, exit JTI mode and the outgoing call test is completed.