Nanjing fire protection declaration process:
Step 1: The applicant goes to the window of the Public Security Bureau of the District Government Service Center to receive the declaration form and notification form;
Step 2 : Applicants should submit relevant materials to the window of the Public Security Bureau of the District Government Service Center, and the window staff will accept the application after preliminary review.
Step 3: Review according to relevant national technical standards within the promised period. If the application meets or does not meet the statutory conditions and standards, a written decision of agreement or disagreement will be made in accordance with the law, and the window staff will reply to the applicant.
Required materials:
1. "Building Fire Protection Design Fire Protection Review Application Form" with the official seal of the applicant;
2. Construction project plan Project approval document issued by the competent department;
3. Have a general floor plan approved by the District Planning Administration (if it is a copy, please stamp it with the official seal of the applicant);
4. Construction A complete set of drawings that should be submitted at each stage of the project's site selection, scheme design, preliminary design, and construction drawing design. The drawings should have the seal of the design institute and the architect's qualification seal.
Note:
1. Fire protection design experts should be provided for high-rise buildings, large public buildings, Category A and B production and warehousing projects and other projects equipped with automatic fire protection facilities. Chapter;
2. Changes in building use or design should be submitted to the original fire department for review and approval before implementation;
3. Building land planning red line map (if it is a copy, Please stamp the applicant’s official seal);
4. Copies of the construction qualification certificate and business license of the construction engineering construction unit and fire protection engineering construction unit (please stamp the applicant’s official stamp);
5. Information on the leakage fire alarm system of high-rise buildings;
6. Projects involving fire protection systems must submit a copy of the construction unit qualification certificate and the engineering company's business license with a fresh seal;
7. When submitting drawings and text materials for review, you can also submit a data CD for review.
The application materials for internal decoration projects are as follows:
1. "Building Internal Decoration Fire Protection Audit Application Form" with the official seal of the relevant unit;
2. The original floor plan of the building on the renovated floor, the original fire protection equipment (electric installation, water installation, wind installation) plan;
3. The "Construction Project Fire Protection Design Review Opinion" or the "Construction Project Fire Protection Acceptance Opinion" of the original building Book";
4. The decoration plan, elevation, section, node details, material list and description of the decoration floor designed by the design unit with corresponding design qualifications, the newly designed fire protection equipment (electrical installation, Water treatment, wind treatment) plane and system diagram;
5. When submitting drawings and written materials for review, a data CD can be submitted for review
Nanjing Yuhuatai District Government Service Center
Address: No. 106, Software Avenue
Transportation: Yinjia Lane - 411 meters from the bus station
Passing buses: No. 46, No. 61, No. 98 Road? No. 99? No. 705, No. 710 Interval? No. 711? No. 719? No. 754? No. 768 No. 780