Setting method
When the key press time exceeds 3s, the digital tube starts flashing, and the system enters the adjustment mode. Loosen the key. Every time you press the key, the number of the digital tube will become a new number until the number displayed by the digital tube matches the number corresponding to the mode selected by the user from the table. When the nixie tube stops flashing or the key is pressed for more than 3 seconds, the setting is completed.
Pure light control
When there is no sunlight, the light intensity drops to the starting point. After the controller delays 10 minute to confirm the start signal, the load starts according to the set parameters and starts to work. When there is sunshine, the light intensity rises to the starting point, and the controller delays 10 minutes to confirm the turn-off signal, then turns off the output and the load stops working.
Light control+time control
The starting process is the same as pure light control. When the load works for a period of time, it will automatically turn off. The setting time is 1 ~ 14 hours.
Manual control
In this mode, whether it is day or night, the user can control the load on and off by pressing the key. This mode is used for some special load cases or debugging.
Debugging mode
Used for system debugging, the load is turned off when there is light signal, and turned on when there is no light signal, which is convenient for checking the correctness of system installation during installation and debugging.
Normally open mode
The electrified load always keeps the output state. This mode is suitable for loads that need 24-hour power supply.