What are the common installation misunderstandings of wall-hung boilers?

1. Place the wall-hung boiler in a humid place: Some users install the wall-hung boiler in the bathroom for ease of use, but the bathroom is humid and can easily cause corrosion of the equipment circuit board, so it cannot be installed in the bathroom or toilet. It is easy to cause short circuit and other accidents. It is more reasonable to install it on a closed balcony or a dry and ventilated kitchen. However, installation on the exterior wall should be avoided, because there are no rainproof, sunshade, lightning protection and other measures, which can easily lead to water intrusion into the smoke pipe, and it is inconvenient to repair if it breaks down.

2. The flue installation slope is too small or no condensate collection device is installed. The wall-hung boiler flue should have a certain slope when installed (the one outside the house is higher than the one inside the house), otherwise the high-temperature flue gas will be discharged to the outside and the condensed water will flow backward into the wall-hung boiler. On rainy days, rainwater will flow back into the wall-mounted boiler. If the vertical flue section exceeds 500 mm, a matching condensate collection device must be installed, otherwise it will also cause the water vapor in the flue gas to condense and flow back. The Little Squirrel wall-mounted boiler has a patented rainwater collection device, which can effectively solve the problem of rainwater backflow and equipment damage. In addition, the Little Squirrel wall-mounted boiler adopts a coaxial flue exhaust design, making it safer indoors and more secure to use.

3. The wall-hung boiler and the radiator are connected in series: When the wall-hung boiler and the radiator are connected to each other, they are directly connected. This can easily increase the resistance of the heating system and affect the normal operation of the heating system.

4. The connecting pipe at the bottom of the wall-mounted boiler has many turns: This will increase the resistance of the water in the heating system and deposit water impurities, which will affect the operation of the system.

5. The installation is not firm: When the wall-mounted boiler is fixed to the wall, if the hooks are not tightly connected, the noise of the wall-mounted boiler may become louder and louder after use. The wall-mounted boiler should be installed correctly and firmly close to the wall to avoid vibration and noise caused by the fan of the wall-mounted boiler during operation.

6. Failure to check the pipeline before installation: Before installing the wall-mounted boiler, check whether the built-in water pump has residual impurities and blockages. If there are any residual impurities, it will add more resistance to the system operation, increase the noise, consume gas, etc. . So you can’t just check it before installation just because it’s new.