Weikang Bi-level Automatic Ventilator Comprehensive introduction to M750:

Philips Respironics PR SYSTEM ONE BiPAP Auto (M750) bi-level automatic pressure-regulating ventilator is a product of the latest generation of Respironics' R&D platform. It is the replacement for Respironics M series ventilators. The latest upgraded product of M700.

PR SYSTEM ONE BiPAP Auto (M750) integrates Weikang’s latest technology and R&D achievements. It is currently a bi-level automatic pressure-regulating home non-invasive ventilator with excellent performance and can automatically track every breath of the user. , according to the user's sleep status, output the minimum pressure to keep the airway open. The improved Bi-Flex technology can provide pressure relief in two phases and create a perfect airflow curve, which is suitable for the treatment of patients with sleep apnea, COPD, cor pulmonale, heart failure, emphysema, asthma, etc.

Weikang bi-level fully automatic ventilator M750 main functions:

1. Working mode: BiPAP, Auto BiPAP, Bi-Fiex, Auto Bi-Fiex2, new heating and humidification The all-in-one anti-backflow device completely and effectively prevents humidification water from flowing back into the main unit. Humidification water will not enter the main unit even if the machine is turned upside down.

3. Auto-Trak digital automatic tracking function: automatically tracks every breath of the patient, detects airflow restriction events, automatically adjusts the output pressure, and is responsive.

4. Bi-Flex exhalation pressure reduction and release patented technology: automatically tracks every breath of the patient, automatically outputs a lowerable pressure according to changes in the patient's exhalation airflow, and the pressure can be adjusted in three levels to achieve optimal comfort. Effect.

5. Preliminary screening diagnosis and pressure titration: Cooperate with blood oxygen monitoring to make a preliminary diagnosis of suspected OSA patients and perform pressure titration and treatment.

6. The memory card is changed to an SD data storage card (portable Encore Por smart card) that can record 365 days of usage. Customers can read the data on their own computers, which is more convenient. Main data records: usage time, respiratory events, pressure range, etc., to evaluate the treatment effect and determine the optimal treatment pressure.

7. Automatic on/off function; automatic altitude pressure compensation function; automatic air leakage compensation function

8. Automatic adjustment function can maintain the minimum and most effective air pressure required