Surface resistance range of anti-static EPE

1) This range is 10^6≤ resistance ≤ 10^11, including two points; but if the standards are different, the range definition of electrostatic dissipative conductors is different; for details, please refer to IEC61340-5- 1. ANSI/ESD S20.20, JESD625-A.

2) 10^11~10^12 power can be considered as the electrostatic insulation range when used. We must look at your protection objects, that is, look at the level requirements of electrostatic sensitive parts and the protective measures you take;

3) The electrostatic protection mechanism must be understood in essence. It is recommended to understand several Concepts: a) The concepts of electrostatic conductors, semiconductors, and insulators 2) The concept of electrostatic protection area (ESDA) and equipotentiality 3) The protection mechanism of electrostatic sensitive devices (ESDS) 4) The concept of grounding; these are very important to guide practical work , can carry out electrostatic protection work understandably.