1. When using the car muffler, it must be at least 300mm below the water surface and 200mm away from the side wall and bottom of the container, and it is best to place it in the geometric center of the container.
2. When selecting the type, the pipe diameter should be greater than or equal to the nominal diameter of the heater. When multiple heaters are used in parallel, the cross-sectional area of the steam pipe should be greater than or equal to the sum of the cross-sectional areas of all heater connecting pipes.
3. When the steam pressure is greater than 0.5MPa (gauge pressure), a steam pressure reducing valve should be installed to reduce the pressure, and a filter should be installed before it.
4, steam pipe near the heater, check valve must be installed, to prevent steam stop, siphon phenomenon, leading to water backflow accident.
5. The steam pipe near the heater should be fixed firmly, so that it will not swing when working.
6. Many heaters are used in parallel and should be evenly distributed. They should be supported because of their heavy weight. Installation and positioning depend on site conditions.
7. The water temperature and water level of the water tank shall be measured and controlled by the temperature controller and water level controller.
8. In use, if the heating speed of the heater is slow, the internal steam hole may be blocked. Century Star introduced that it is necessary to remove the heater, remove impurities blocking the steam hole, and discharge the sewage from the sewage outlet. It is best to clean the heater once a month.