Different lubricating oils are prohibited from mixing with each other. The positions of oil level plug, oil drain plug and vent hole are determined by the installation position.
Reducer (solid drawing)
Oil level check:
1, cut off the power supply to prevent electric shock. Wait for the reducer to cool down;
2. Remove the oil level plug and check whether the oil is full;
3. Install the oil level plug.
Inspection of oil:
1, cut off the power supply to prevent electric shock. Wait for the reducer to cool down;
2. Open the oil plug and take an oil sample;
3. Check the viscosity index of the engine oil: if the engine oil is obviously turbid, it is recommended to replace it as soon as possible;
4. For the reducer with oil level plug; Check whether the oil level is qualified; Install the oil level plug.
Oil change:
After cooling, the viscosity of the oil increases and it is difficult to discharge the oil. Therefore, the reducer should be replaced at the working temperature.
1, cut off the power supply to prevent electric shock. Wait for the reducer to cool, there is no danger of burning;
Note: the reducer should still be warm when changing oil;
2. Put an oil pan under the oil drain plug;
3. Open the oil level plug, vent hole and oil drain plug;
4. Remove all the oil;
5. Install the oil drain plug;
6. Inject new oil of the same brand;
7, oil quantity should be consistent with the installation position;
8. Check the oil level at the oil level plug;
9. Tighten the oil level plug and vent hole.