Solution: Replace the genuine carrier again; Carrier initialization must be carried out after carrier installation; Different models have different initialization steps. Please contact the installer directly for help. If you don't know how to initialize the carrier after replacing it, it is recommended to complete this operation under the guidance of a technical master.
2. It may be that the sensor of the copier is damaged. First of all, the sensor is a consumable, and there will be many situations when it is printed to a certain number of sheets. It is still necessary to spend money for a new one, otherwise it will delay your own business and waste copy paper. There is no other way. It is recommended to contact the after-sales replacement sensor for testing.
3. Reinitialization operation of the copier. Solution: Open the front cover, enter the maintenance mode, select TCR AUTO, do not press "Menu/Select", close the front door and press it again. The actions of closing and pressing should be consistent, and then the machine will be automatically reinitialized.
Extended data:
1, C0000 motor failure
After a set period of time passes after the transmission motor runs, the locking signal of the transmission motor is still set to H.
2. Motor failure of 2.C00 10/0 imaging unit
After a set period of time has passed after the motor of the imaging unit runs, the locking signal of the motor of the imaging unit is still set to H. After a set period of time passes after the motor of the imaging unit stops running, the imaging spindle arrival signal is still set to L.
3.C0044 EDH fan motor failure? For more information about related options, please refer to the service manual.
4.C0045 cooling fan failure
After the cooling fan motor runs for a set period of time, the locking signal of the cooling fan motor is still set to H. After the cooling fan motor stops running for a set period of time, the locking signal of the cooling fan motor is still set to L.
5, C004E power supply unit cooling fan failure.
After the power supply cooling fan motor runs for a period of time, the power supply cooling fan motor locking signal is still set to H. After the power supply equipment cooling fan motor stops running for a period of time, the power supply equipment cooling fan motor locking signal is still set to L.