Household steamer can't drip into it.
Cause of steam room failure: the steam room is not heated. Check the air switch group in the steaming room to see if any air switch is broken and replace it in time. Check whether the alternator is attracted when the steaming room is electrified. Check whether the connector of the line is loose due to thermal expansion and contraction, and tighten the air switch screw in real time. The temperature of the wall or floor of the steaming room is slow * Check whether the set temperature of the thermostat is lower than the measured temperature. If the set temperature is higher than the measured temperature, observe whether the thermostat working indicator lamp is in working condition, otherwise the thermostat will fail and be replaced with the manufacturer in time. Excluding the above situation, we can check whether the temperature sensor of the steaming room is too close to the heating wall or the ground, which leads to instantaneous power failure and slow heating. You can try to keep the thermostatic probe away from the heating area. 3. The thermostat of the steaming room shows p5: Then it can be concluded that the sensor of the steaming room is on. Don't deal with the problem of steaming room at will. Feedback the problems of the steaming room to the manufacturer for maintenance or carry out maintenance under the guidance of technicians. 5. It is forbidden to nail the wall and floor with nails or other sharp tools without guidance in the steaming room.