What are the control points of safety supervision of pile foundation engineering?

What are the control points of safety supervision of pile foundation engineering?

1. Electricians, welders, crane drivers, pile drivers and other special operators must receive professional training and hold valid certificates.

2. Before the project starts, the construction machinery and tools must be inspected and approved, and the equipment entering the site must have the use certificate and be monitored. During the effective use period, the model and specifications of the equipment entering the site are consistent with the construction plan.

3. Before the construction of this sub-project, the safety disclosure must be carried out at the same time as the technical disclosure, and signed by the person being disclosed for future reference.

4. Machinery must be used reasonably under specified operating conditions and correct bearing capacity. It is strictly forbidden to expand the scope of use at will, and strictly implement the "ten don't lift" regulations.

5. All kinds of mechanical safety protection devices must be complete and effective, and any incomplete or partial failure or malfunction safety protection device shall not be used.

6. When lifting, the lifting must keep a specified safe distance, and the non-operating personnel shall not stay within the movement range of the rotating machinery below the boom.

7. The electrical box should be installed in a dry, ventilated place without sundries and impact, with firm installation and standard wiring.

8. The cable should be pulled out of the temporary distribution box during the piling stage. The overhead cable should be greater than 0.8m, and the buried depth of the passing cable should be less than 0.6m, and covered with yellow sand.

9. When the pile driver is walking, there must be full-time personnel to command, and the operator has a clear division of labor. It is forbidden to leave the post without permission, and check the safety of the mechanical walking route to ensure the safety of the mobile machine.

10. Observe the "ten incombustible" regulations of electric welding, and the distance between oxygen and fire source shall not be less than 10 meter; The distance between acetylene cylinder and oxygen cylinder shall not be less than 5 meters.